Chartered Surveyors , Geospatial Engineers
 
 
 
  • Homepage
  • Generic Services
  • Sector Services
  • Our Approach
  • Capabilities
  • Survey Consultancy
  • 3D Laser Scanning
    • Introduction
    • Uses of Scan Data
    • Benefits of Scanning
    • Deliverables
    • Scanning Software
    • Links to Gallery
  • Proving As Built
  • Topographical Land
    • Topographical
    • Sections
    • River Surveys
    • Areas & Volumes
    • Precise Levelling
    • Digital Terrain Models
  • Engineering
  • GPS & Survey Control
    • Plan Control
    • Long Thin Surveys
  • Photogrammetry
  • Measured Building
    • Floor Plans
    • Elevations
    • Roof Plans
    • Sections
    • Licencing Act 2003
  • Geotechnical
  • 3D Modelling
  • Utility Location
  • Monitoring
  • Trees & Woodland
Measured Building Survey - Licensing Act 2003 (Regulation 23)
  
The Licensing Act 2003 (View) sets out a number of requirements relating to the creation of a dimensionally correct plan.

In summary: The plan shall show -
 
  (a) the extent of the boundary of the building, if relevant, and any external and internal walls of the building and, if different, the perimeter of the premises;

(b) the location of points of access to and egress from the premises;

(c) if different from sub-paragraph (3)(b), the location of escape routes from the premises;

(d) in a case where the premises is to be used for more than one licensable activity, the area within the premises used for each activity;

(e) fixed structures (including furniture) or similar objects temporarily in a fixed location (but not furniture) which may impact on the ability of individuals on the premises to use exits or escape routes without impediment;

(f) in a case where the premises includes a stage or raised area, the location and height of each stage or area relative to the floor;

(g) in a case where the premises includes any steps, stairs, elevators or lifts, the location of the steps, stairs, elevators or lifts;

(h) in the case where the premises includes any room or rooms containing public conveniences, the location of the room or rooms;

(i) the location and type of any fire safety and any other safety equipment including, if applicable, marine safety equipment; and

(j) the location of a kitchen, if any, on the premises..

We can provide this as a hard copy, 1:100 scale plan in the format required, with all the above detail shown
Please call us to discuss your requirements
 